A1221 ANCHOR – Ultrasonic Anchor Bolt Testing
An ultrasonic low-frequency tester for in-situ quality assessment of concrete anchors, solid rebars and reinforcement.
A1221 ANCHOR is an ultrasonic instrument for in-situ evaluation of embedded meta…
Description
An ultrasonic low-frequency tester for in-situ quality assessment of concrete anchors, solid rebars and reinforcement.
A1221 ANCHOR is an ultrasonic instrument for in-situ evaluation of embedded metallic elements by means of low-frequency ultrasonic waves.
The main application field of A1221 ANCHOR is the non-destructive testing of anchor bolts and similar structural elements.
Following evaluations can be performed by placing ultrasonic transducer on the free outer end of the bolt:
- Detection of anchor breaks
- Residual length/fraction assessment
- Adhesion quality assessment
Application features:
| Assessable bolt / rebar diameter | 20-40 millimeters (0.8-1,6 inch) |
| Not grouted assessment length | up to 8 meters (26.3 feet) |
| Minimal assessment length | 0.3 meter (9.8 feet) |
| Assessable grouting depth in concrete: | up to 1 meter (3.3 feet) |
| Assessable grouting depth in rock: | up to 4 meters (13.1 feet) |
Specification
| Parameter | Value |
| Operating frequency range, kHz | 25-250 |
| Maximal data acquisition length, μs | 4000 |
| Assessment length, m | 0.5-3 |
| Assessment length of embedded rods, m | up to 1 |
| Assessable rod diameter range, mm | 20-40 |
| Material velocity range, m/s | 500-15000 |
| Transmitter output voltage, V | ±20, ±100, ±200 |
| Transmitter pulse form | Bipolar meander, 0.5÷5.0 periods |
| Pulse repetition rate, Hz | 1-45 |
| Gain setup range, dB | 0-100, step 1 |
| Number of the programmable points of DAC function | 24 |
| Dynamic range of DAC function, dB | 30 |
| Power supply | Built-in battery |
| Operation time, h | 14 |
| Battery charging time, h | 3 |
| Display type | TFT (640 х 480) |
| Electronic unit dimensions, mm | 260×156×43 |
| Electronic unit weight, kg | 0.8 |
| Operational conditions | |
| Operating temperature range, ºC | from -20 to +45 |
| Relative air humidity at +35°С, %, max | 95 |
Documentation
Applications of the A1221 Anchor
The A1221 Anchor is an ultrasonic low-frequency tester developed for in-situ quality assessment of concrete anchors, solid rebars and reinforcement directly on site.
By placing the ultrasonic transducer on the free outer end of a bolt, the operator can verify the integrity of embedded metallic elements without destructive sampling or pull-out tests.
The A1221 Anchor detects anchor breaks along the embedded length, assesses residual length or the remaining fraction of a damaged anchor, and evaluates the quality of adhesion between the anchor and the surrounding material.
This makes the instrument valuable for acceptance testing of newly installed anchors, periodic inspection of load-bearing fasteners in bridges, tunnels, industrial facilities and retaining structures, and forensic assessment after suspected anchor failure.
Because the method relies on low-frequency ultrasonic waves propagating through the metallic element, it remains effective on long anchors — non-grouted assessment lengths reach up to 8 meters — and in difficult media such as grouted concrete and rock.
The A1221 Anchor supports grouting-depth assessment of up to 1 meter in concrete and up to 4 meters in rock, covering bolts and rebars with diameters from 20 to 40 mm.
Field crews benefit from the instrument’s compact 800 g electronic unit, 14-hour battery operation and intuitive interface, which allow full-day inspection campaigns on construction sites and in tunnels without recharging.
A1221 Anchor key features
- The A1221 Anchor evaluates anchor bolts and solid rebars with diameters from 20 to 40 mm (0.8–1.6 inch), covering the most common structural fastener sizes
- Non-grouted assessment length of up to 8 meters (26.3 feet) with a minimal assessment length of just 0.3 meter
- Assessable grouting depth of up to 1 meter (3.3 feet) in concrete and up to 4 meters (13.1 feet) in rock
- Low-frequency operation from 25 to 250 kHz with a maximum data acquisition length of 4000 μs
- The A1221 Anchor drives the transducer with ±20, ±100 and ±200 V bipolar meander pulses of 0.5–5.0 periods at 1–45 Hz repetition rate
- Material velocity range of 500–15000 m/s, gain adjustable from 0 to 100 dB in 1 dB steps, and 24 programmable DAC points with 30 dB dynamic range
- Portable 800 g electronic unit with a 640 x 480 TFT display, 14 hours of battery operation and −20 to +45 °C operating temperature range
Related instruments: ultrasonic concrete testing instruments.