A2075 SoNet
Noncontact ultrasonic scanner-flaw detector А2075 SoNet is applicable for automatic flaws search in the metal pipe’s walls of 1020 ÷ 1420 mm in diameter and with thickness starting from 6mm.
Operatin…
Noncontact ultrasonic scanner-flaw detector А2075 SoNet is applicable for automatic flaws search in the metal pipe’s walls of 1020 ÷ 1420 mm in diameter and with thickness starting from 6mm.
Operating principle of the scanner- flaw detector is a wave guided pulse echo inspection technique excitation (sending) and receiving of ultrasonic waves in a pipe’s body is made without a contact (without using a couplant) with a help of electro-magnetic acoustic (EMA) transducers.
Detection of a stress-corrosion and corrosion flaws in the pipe’s body. Detection of flaws in flats (sheet products) with indication of flaw’s quantity, relative dimensions and locations (coordinates).
Noncontact ultrasonic scanner-flaw detector А2075 SoNet is applicable for automatic flaws search in the metal pipe’s walls of 1020 ÷ 1420 mm in diameter and with thickness starting from 6mm.
Operating principle of the scanner- flaw detector is a wave guided pulse echo inspection technique excitation (sending) and receiving of ultrasonic waves in a pipe’s body is made without a contact (without using a couplant) with a help of electro-magnetic acoustic (EMA) transducers.
Detection of a stress-corrosion and corrosion flaws in the pipe’s body. Detection of flaws in flats (sheet products) with indication of flaw’s quantity, relative dimensions and locations (coordinates).
Specifications
| Velocity | 3020 m/s |
| Operating frequency | 0.5 MHz |
| Range of the calibrated amplifier | 0-40 dB |
| Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws along the circumference of the pipe, not more than | ±100 mm |
| Limit of the acceptable basic absolute accuracy in measuring of the coordinates of the flaws towards the pipe, not more than | ±20 mm |
| Maximum sensitivity of the receiver, not less than | 20 mKV |
| Measurement accuracy of the amplitude ratio of signals at the receiver input, not more than | ±1 dB |
| Power | Accumulator blocks |
| Voltage | 12 V |
| Operating time (accumulator) | 8 h |
| Weight | 42 kg |
| Average error-free running time | 30000 hours |
| Average lifetime, not less than | 4 years |
| Operation conditions: air temperature | from -40 to +50°C |
| relative air humidity at a temperature of +35 °С, not more than | 95% |
| Dimensions | 407 х 655 х 407 mm |